{"id":10703,"date":"2025-03-25T10:04:43","date_gmt":"2025-03-25T10:04:43","guid":{"rendered":"https:\/\/www.ctube-gr.com\/?p=10703"},"modified":"2025-04-07T08:08:14","modified_gmt":"2025-04-07T08:08:14","slug":"principales-differences-entre-les-types-de-conduits-electriques-sch40-sch80-db60-db100-db120-type-a-et-type-eb","status":"publish","type":"post","link":"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html","title":{"rendered":"Principales diff\u00e9rences entre les types de conduits \u00e9lectriques\u00a0: SCH40 vs SCH80 vs DB60 vs DB100 vs DB120 vs Type A vs Type EB"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table des mati\u00e8res<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Basculer la table des mati\u00e8res\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Basculer<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #444444;color:#444444\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #444444;color:#444444\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#1_Introduction\" >1. Introduction<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#11_Why_Conduit_Specifications_Matter\" >1.1 Pourquoi les sp\u00e9cifications des conduits sont importantes<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#12_Referencing_Key_Standards\" >1.2 R\u00e9f\u00e9rencement des normes cl\u00e9s<\/a><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#2_Understanding_Different_Conduit_Series_SCH_VS_DB_VS_EB_VS_A\" >2. Comprendre les diff\u00e9rentes s\u00e9ries de conduits\u00a0: SCH VS DB VS EB VS A<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#21_What_Are_Conduit_Schedules\" >2.1 Que sont les programmes de conduits\u00a0?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#22_SCH_40_VS_80_PVC_Conduit\" >2.2 Conduit PVC SCH 40 VS 80<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#23_What_is_Type_DB_Conduit\" >2.3 Qu&#039;est-ce que le conduit de type DB\u00a0?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#24_What_is_Type_EB_Conduit\" >2.4 Qu&#039;est-ce qu&#039;un conduit de type EB ?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#25_What_is_Type_A_Conduit\" >2.5 Qu&#039;est-ce qu&#039;un conduit de type A ?<\/a><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#3_Key_Differences_in_Different_Types_of_PVC_Conduit\" >3. Principales diff\u00e9rences entre les diff\u00e9rents types de conduits en PVC<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#31_Size_Wall_thickness_of_Different_Types_of_Conduits\" >3.1 Taille et \u00e9paisseur de paroi des diff\u00e9rents types de conduits<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#32_Material_Requirements_ASTM_D1784\" >3.2 Exigences mat\u00e9rielles : ASTM D1784<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#33_Usage_Restrictions_and_Temperature_Ratings\" >3.3 Restrictions d&#039;utilisation et temp\u00e9ratures nominales<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#34_Other_Requirements\" >3.4 Autres exigences<\/a><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#4_PVC_Conduit_Application_introduce_SCH_40_SCH_80_Type_EB_Type_DB_Type_A\" >4. Pr\u00e9sentation des applications de conduits en PVC\u00a0: SCH 40, SCH 80, type EB, type DB, type A<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#41_General_Applications_of_PVC_Conduit\" >4.1 Applications g\u00e9n\u00e9rales des conduits en PVC<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#42_Differences_in_Specialized_Applications\" >4.2 Diff\u00e9rences dans les applications sp\u00e9cialis\u00e9es<\/a><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#5_How_to_Choose_Between_SCH_40_SCH_80_Type_DB_Type_EB_and_Type_A\" >5. Comment choisir entre SCH 40, SCH 80, Type DB, Type EB et Type A<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#51_Mechanical_Strength_and_Durability\" >5.1 R\u00e9sistance m\u00e9canique et durabilit\u00e9<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#52_Installation_Environment_Underground_vs_Aboveground\" >5.2 Environnement d&#039;installation : souterrain ou a\u00e9rien<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#53_Cost_and_Budget_Considerations\" >5.3 Consid\u00e9rations relatives aux co\u00fbts et au budget<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#54_Compliance_and_Regulatory_Standards\" >5.4 Conformit\u00e9 et normes r\u00e9glementaires<\/a><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/www.ctube-gr.com\/fr\/news\/key-differences-in-electrical-conduits-typessch40-vs-sch80-vs-db60-vs-db100-vs-db120-vs-type-a-vs-type-eb.html\/#6_Conclusion\" >6. Conclusion<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"1_Introduction\"><\/span>1. Introduction<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Les conduits \u00e9lectriques prot\u00e8gent les c\u00e2bles contre les dommages environnementaux, les chocs physiques et la corrosion.<\/p>\n<p>Lors du choix d&#039;une gaine \u00e9lectrique, le mat\u00e9riau est souvent l&#039;un des premiers crit\u00e8res pris en compte. Cependant, lorsqu&#039;il s&#039;agit de choisir entre des gaines fabriqu\u00e9es dans le m\u00eame mat\u00e9riau, l&#039;attention se porte g\u00e9n\u00e9ralement sur la taille et le type de gaine.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"11_Why_Conduit_Specifications_Matter\"><\/span>1.1 Pourquoi les sp\u00e9cifications des conduits sont importantes<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Des sp\u00e9cifications telles que SCH40, SCH80, DB60, DB100, DB120, Type A et Type EB d\u00e9finissent des diff\u00e9rences critiques en termes d&#039;\u00e9paisseur de paroi, de durabilit\u00e9 et d&#039;ad\u00e9quation \u00e0 l&#039;application.<\/p>\n<p>Ces classifications garantissent la conformit\u00e9 aux codes de s\u00e9curit\u00e9 (par exemple, le Code national de l&#039;\u00e9lectricit\u00e9\u00ae) et aux normes de performance. Ces d\u00e9signations sp\u00e9cifiques sont universellement comprises et exig\u00e9es par les lecteurs en Am\u00e9rique du Nord en raison de leur adoption historique, des cadres r\u00e9glementaires et de la disponibilit\u00e9 des mat\u00e9riaux.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-10712\" src=\"https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/UL-651-NEMA-TC2-6-8-1024x444.jpg\" alt=\"UL 651 NEMA TC2, 6, 8\" width=\"800\" height=\"347\" srcset=\"https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/UL-651-NEMA-TC2-6-8-1024x444.jpg 1024w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/UL-651-NEMA-TC2-6-8-300x130.jpg 300w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/UL-651-NEMA-TC2-6-8-768x333.jpg 768w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/UL-651-NEMA-TC2-6-8-1536x666.jpg 1536w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/UL-651-NEMA-TC2-6-8-2048x888.jpg 2048w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/UL-651-NEMA-TC2-6-8-18x8.jpg 18w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/UL-651-NEMA-TC2-6-8-600x260.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h4><span class=\"ez-toc-section\" id=\"12_Referencing_Key_Standards\"><\/span>1.2 R\u00e9f\u00e9rencement des normes cl\u00e9s<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Cet article fait r\u00e9f\u00e9rence aux normes de l&#039;industrie pour clarifier les exigences relatives aux conduits\u00a0:<\/p>\n<p><a href=\"https:\/\/www.ul.com\/\" rel=\"nofollow noopener\" target=\"_blank\"><strong>UL 651<\/strong><\/a>: Norme de s\u00e9curit\u00e9 pour les conduits et raccords en PVC rigide (couvre SCH40, SCH80, Type EB et Type A).<\/p>\n<p><a href=\"https:\/\/www.makeitelectric.org\/\" rel=\"nofollow noopener\" target=\"_blank\"><strong>NEMA<\/strong><\/a><strong> TC 2<\/strong> :Norme pour les conduits \u00e9lectriques en polychlorure de vinyle (PVC) (plus de SCH40, SCH80).<\/p>\n<p><strong>NEMA TC 6 et 8<\/strong> :Norme relative aux conduits en plastique de chlorure de polyvinyle (PVC) pour installations souterraines (r\u00e9git DB60, DB100, DB120, EB20 et EB35).<\/p>\n<p>Note aux lecteurs : Pour des sp\u00e9cifications techniques d\u00e9taill\u00e9es, consultez toujours les documents officiels :<\/p>\n<p>Achetez UL 651 directement aupr\u00e8s d\u2019UL Solutions.<\/p>\n<p>Acc\u00e9dez \u00e0 NEMA TC 6 &amp; 8-2013 via la National Electrical Manufacturers Association (NEMA).<\/p>\n<h2><span class=\"ez-toc-section\" id=\"2_Understanding_Different_Conduit_Series_SCH_VS_DB_VS_EB_VS_A\"><\/span>2. Comprendre les diff\u00e9rentes s\u00e9ries de conduits\u00a0: SCH VS DB VS EB VS A<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Dans la classification des conduits rigides en PVC, les types SCH, DB, EB et Type A partagent certaines similitudes, mais poss\u00e8dent \u00e9galement des caract\u00e9ristiques distinctes qui les distinguent. Pour une meilleure compr\u00e9hension, nous pr\u00e9senterons ces types de conduits s\u00e9par\u00e9ment, en soulignant leurs diff\u00e9rences, leurs points communs et leurs applications sp\u00e9cifiques.<\/p>\n<p>Selon les normes UL 651, SCH 40 et 80, les conduits de type EB (enfouissement encastr\u00e9) et de type A sont souvent compar\u00e9s, car ils sont tous deux con\u00e7us pour des installations enrob\u00e9es de b\u00e9ton, mais diff\u00e8rent en termes de r\u00e9sistance et de champ d&#039;application. Par ailleurs, les normes NEMA TC 6 et 8 comparent les conduits DB (enfouissement direct) et EB, car tous deux sont destin\u00e9s \u00e0 une utilisation souterraine, mais diff\u00e8rent par leurs m\u00e9thodes d&#039;enfouissement et leurs capacit\u00e9s de charge.<\/p>\n<p>Pour \u00e9viter toute confusion et faciliter la lecture, nous analyserons chaque type s\u00e9par\u00e9ment dans les sections suivantes.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"21_What_Are_Conduit_Schedules\"><\/span>2.1 Que sont les programmes de conduits\u00a0?<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Le \u00ab\u00a0schedule\u00a0\u00bb (abr\u00e9g\u00e9 en \u00ab\u00a0Sch\u00a0\u00bb) d&#039;un conduit d\u00e9signe l&#039;\u00e9paisseur de sa paroi. Plus le chiffre est \u00e9lev\u00e9, plus la paroi est \u00e9paisse. Par exemple, le Schedule\u00a080 a une paroi plus \u00e9paisse que le Schedule\u00a040, m\u00eame si les deux ont le m\u00eame diam\u00e8tre ext\u00e9rieur.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"22_SCH_40_VS_80_PVC_Conduit\"><\/span>2.2 Conduit PVC SCH 40 VS 80<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p><a href=\"https:\/\/www.ctube-gr.com\/fr\/conduit-en-pvc-de-la-serie-40-de-ctube-tuyau-electrique-de-la-serie-40-1-2-8-po-x-10-pi-gris\/\"><strong>SCH 40 Conduit \u00e9lectrique<\/strong><\/a> Con\u00e7u pour des applications normales en surface, avec enrobage en b\u00e9ton ou enfouissement direct. Peut \u00eatre qualifi\u00e9 de \u00ab\u00a0mur lourd\u00a0\u00bb.<\/p>\n<p><span style=\"color: #003473;\"><strong><a style=\"color: #003473;\" href=\"https:\/\/www.ctube-gr.com\/fr\/conduit-en-pvc-de-la-serie-80-de-ctube-tuyau-de-conduit-de-1-2-8-po-x-10-pi-gris\/\">SCH 80 Conduit \u00e9lectrique<\/a><\/strong><\/span> Con\u00e7u pour les applications lourdes (zones de dommages physiques) en surface, les applications avec enrobage de b\u00e9ton ou l&#039;enfouissement direct. Peut \u00eatre qualifi\u00e9 de \u00ab\u00a0mur extra-lourd\u00a0\u00bb.<\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-10704\" src=\"https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/ctube-schedule-40-and-80-conduit.jpg\" alt=\"conduit ctube schedule 40 et 80\" width=\"800\" height=\"562\" srcset=\"https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/ctube-schedule-40-and-80-conduit.jpg 1000w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/ctube-schedule-40-and-80-conduit-300x211.jpg 300w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/ctube-schedule-40-and-80-conduit-768x540.jpg 768w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/ctube-schedule-40-and-80-conduit-18x12.jpg 18w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/ctube-schedule-40-and-80-conduit-600x422.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Le conduit rigide en PVC Schedule 80 pr\u00e9sente des parois plus \u00e9paisses que le Schedule 40, offrant ainsi une protection m\u00e9canique renforc\u00e9e. Il peut \u00eatre utilis\u00e9 dans toutes les applications o\u00f9 le Schedule 40 est autoris\u00e9, y compris les installations sur poteaux conformes aux normes NEC (NFPA 70).<\/p>\n<h4><span class=\"ez-toc-section\" id=\"23_What_is_Type_DB_Conduit\"><\/span>2.3 Qu&#039;est-ce que le conduit de type DB\u00a0?<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Les syst\u00e8mes de conduits \u00e9lectriques souterrains n\u00e9cessitent une protection ad\u00e9quate pour garantir leur long\u00e9vit\u00e9 et leur fiabilit\u00e9. Les conduits \u00e0 enfouissement direct (DB) sont sp\u00e9cialement con\u00e7us pour les applications enfouies, \u00e9liminant ainsi le besoin d&#039;enrobage dans le b\u00e9ton. Les produits de type DB peuvent \u00e9galement \u00eatre utilis\u00e9s pour des applications enrob\u00e9es de b\u00e9ton, le cas \u00e9ch\u00e9ant.<\/p>\n<p>Cependant, tous les conduits class\u00e9s DB ne sont pas identiques : DB60, DB100 et <a href=\"https:\/\/www.ctube-gr.com\/fr\/conduit-rigide-en-pvc-pour-conduit-utilitaire-enterre-direct-ctube-db120\/\"><strong><span style=\"color: #003473;\">DB120<\/span> <\/strong><\/a>sont class\u00e9s en fonction de leur \u00e9paisseur de paroi, de leur r\u00e9sistance m\u00e9canique et de leur ad\u00e9quation \u00e0 diff\u00e9rentes profondeurs d&#039;enfouissement et conditions de charge.<\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-10706\" src=\"https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/CTUBE-DB2-conduit-underground.jpg\" alt=\"Conduit souterrain CTUBE-DB2\" width=\"800\" height=\"568\" srcset=\"https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/CTUBE-DB2-conduit-underground.jpg 977w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/CTUBE-DB2-conduit-underground-300x213.jpg 300w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/CTUBE-DB2-conduit-underground-768x546.jpg 768w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/CTUBE-DB2-conduit-underground-18x12.jpg 18w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/CTUBE-DB2-conduit-underground-600x426.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>L&#039;\u00e9paisseur de la paroi et la r\u00e9sistance du mat\u00e9riau augmentent \u00e0 mesure que le nombre de DB augmente, ce qui rend les conduits \u00e0 DB plus \u00e9lev\u00e9s adapt\u00e9s \u00e0 un enfouissement plus profond et \u00e0 des charges plus lourdes.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"24_What_is_Type_EB_Conduit\"><\/span>2.4 Qu&#039;est-ce qu&#039;un conduit de type EB ?<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p><a href=\"https:\/\/www.ctube-gr.com\/fr\/conduit-electrique-enterre-direct-de-type-ctube-eb\/\"><span style=\"color: #003473;\"><strong>Conduit EB (enfouissement encastr\u00e9)<\/strong><\/span><\/a> Il s&#039;agit d&#039;un type de conduit en PVC sp\u00e9cialement con\u00e7u pour \u00eatre enterr\u00e9 dans du b\u00e9ton. Il est couramment utilis\u00e9 dans les syst\u00e8mes \u00e9lectriques souterrains, o\u00f9 la protection contre la pression du sol et les chocs m\u00e9caniques est g\u00e9n\u00e9ralement de type EB20 et EB35.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10707\" src=\"https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/Ctube-UL-type-EB-underground-conduit.jpg\" alt=\"Conduit souterrain EB de type Ctube-UL\" width=\"800\" height=\"527\" srcset=\"https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/Ctube-UL-type-EB-underground-conduit.jpg 1000w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/Ctube-UL-type-EB-underground-conduit-300x198.jpg 300w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/Ctube-UL-type-EB-underground-conduit-768x506.jpg 768w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/Ctube-UL-type-EB-underground-conduit-18x12.jpg 18w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/Ctube-UL-type-EB-underground-conduit-600x395.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h4><span class=\"ez-toc-section\" id=\"25_What_is_Type_A_Conduit\"><\/span>2.5 Qu&#039;est-ce qu&#039;un conduit de type A ?<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p><a href=\"https:\/\/www.ctube-gr.com\/fr\/conduit-electrique-rigide-en-pvc-de-type-ctube\/\"><span style=\"color: #003473;\"><strong>Conduit rigide en PVC de type A<\/strong><\/span><\/a> est un conduit \u00e9lectrique durable et \u00e0 haute r\u00e9sistance con\u00e7u pour divers environnements d&#039;installation.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10705\" src=\"https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/ctube-type-a-pvc-conduit.jpg\" alt=\"conduit en PVC de type ctube a\" width=\"800\" height=\"550\" srcset=\"https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/ctube-type-a-pvc-conduit.jpg 1000w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/ctube-type-a-pvc-conduit-300x206.jpg 300w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/ctube-type-a-pvc-conduit-768x528.jpg 768w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/ctube-type-a-pvc-conduit-18x12.jpg 18w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/ctube-type-a-pvc-conduit-600x413.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Contrairement aux conduits de type EB, qui se limitent \u00e0 l&#039;enrobage du b\u00e9ton dans les tranch\u00e9es \u00e0 l&#039;ext\u00e9rieur des b\u00e2timents, les conduits de type A offrent des applications plus larges, ce qui en fait un choix id\u00e9al pour les projets d&#039;infrastructure \u00e9lectrique exigeants.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"3_Key_Differences_in_Different_Types_of_PVC_Conduit\"><\/span>3. Principales diff\u00e9rences entre les diff\u00e9rents types de conduits en PVC<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h4><span class=\"ez-toc-section\" id=\"31_Size_Wall_thickness_of_Different_Types_of_Conduits\"><\/span>3.1 Taille et \u00e9paisseur de paroi des diff\u00e9rents types de conduits<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<table>\n<tbody>\n<tr>\n<td><strong>Taille commerciale du conduit<\/strong><\/td>\n<td colspan=\"8\"><strong>\u00c9paisseurs minimales des parois<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td colspan=\"5\"><span style=\"font-weight: 400;\">Minidules d&#039;\u00e9lasticit\u00e9 400 000 psi<\/span><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">pouces<\/span><\/td>\n<td><strong>SCH40<\/strong><\/td>\n<td><strong>SCH80<\/strong><\/td>\n<td><strong>DB60<\/strong><\/td>\n<td><strong>DB100<\/strong><\/td>\n<td><strong>DB120<\/strong><\/td>\n<td><strong>EB20<\/strong><\/td>\n<td><strong>EB35<\/strong><\/td>\n<td><strong>TypeA<\/strong><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">1\/2<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.109\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.147\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.080\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">3\/4<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.113\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.154\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.080\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">1<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.133\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.179\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.060\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.080\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">1-1\/4<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.140\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.191\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.090\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">1-1\/2<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.145\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.200\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.060\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.065\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.100\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">2<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.154\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.218\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.065\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.083\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.060\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.120\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">2-1\/2<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.203\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.276\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.130\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>3<\/b><\/td>\n<td><b>0.216\u00a0<\/b><\/td>\n<td><b>0.300\u00a0<\/b><\/td>\n<td><b>0.100\u00a0<\/b><\/td>\n<td><b>0.121\u00a0<\/b><\/td>\n<td><b>0.127\u00a0<\/b><\/td>\n<td><b>0.067\u00a0<\/b><\/td>\n<td><b>0.082\u00a0<\/b><\/td>\n<td><b>0.145\u00a0<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">3-1\/2<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.226\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.318\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.115\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.138\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.147\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.078\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.095\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.165\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">4<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.237\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.337\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.131\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.155\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.166\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.089\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.109\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.170\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">5<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.258\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.375\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.164\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.192\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.205\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.112\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.136\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">6<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.280\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.432\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.196\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.229\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.244\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.135\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.164\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\/<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Nous prenons la m\u00eame taille pour voir les r\u00e9sultats de l&#039;\u00e9paisseur de paroi des diff\u00e9rents conduits dans le m\u00eame cas comme suit : SCH 80 \uff1e SCH 40 \uff1e Type A \uff1e DB120 \uff1e DB100\uff1e DB60 \uff1e EB35 \uff1e EB20<\/p>\n<h4><span class=\"ez-toc-section\" id=\"32_Material_Requirements_ASTM_D1784\"><\/span>3.2 Exigences mat\u00e9rielles : ASTM D1784<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>La norme ASTM D1784 \u00e9tablit un syst\u00e8me de classification pour les compos\u00e9s rigides en PVC et CPVC, en se concentrant sur les propri\u00e9t\u00e9s cl\u00e9s des mat\u00e9riaux essentiels \u00e0 la fabrication de conduits.<\/p>\n<p><strong>Type de r\u00e9sine de base<\/strong>: Assure la coh\u00e9rence chimique.<\/p>\n<p><strong>R\u00e9sistance aux chocs<\/strong>:R\u00e9sistance minimale aux chocs par entaille (par exemple, 12123 inclut une r\u00e9sistance aux chocs \u2265 1 pi\u00b7lb\/po).<\/p>\n<p><strong>R\u00e9sistance \u00e0 la traction<\/strong>:Minimum 6 500 psi (pour le PVC).<\/p>\n<p><strong>Module d&#039;\u00e9lasticit\u00e9<\/strong>:Minimum 400 000 psi (rigidit\u00e9).<\/p>\n<p><strong>Temp\u00e9rature de d\u00e9flexion<\/strong>:R\u00e9sistance \u00e0 la d\u00e9formation sous l&#039;effet de la chaleur.<\/p>\n<p><strong>Inflammabilit\u00e9<\/strong>:Conformit\u00e9 aux normes de s\u00e9curit\u00e9 incendie.<\/p>\n<p><strong>Mat\u00e9riaux recycl\u00e9s<\/strong>:Les deux normes autorisent le PVC recycl\u00e9 s&#039;il r\u00e9pond aux exigences m\u00e9caniques et chimiques, garantissant ainsi la durabilit\u00e9 sans compromettre les performances.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"33_Usage_Restrictions_and_Temperature_Ratings\"><\/span>3.3 Restrictions d&#039;utilisation et temp\u00e9ratures nominales<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Conform\u00e9ment \u00e0 l\u2019exigence mentionn\u00e9e dans la norme UL 651, nous concluons ce qui suit.<\/p>\n<p><strong>3.3.1 Conduits SCH 40 et 80<\/strong><\/p>\n<p>Les conduits de s\u00e9rie 40 et de s\u00e9rie 80 sont con\u00e7us pour \u00eatre utilis\u00e9s dans des environnements avec des temp\u00e9ratures ambiantes allant jusqu&#039;\u00e0 50 \u00b0C (122 \u00b0F).<\/p>\n<p>Lorsqu&#039;ils sont utilis\u00e9s avec un c\u00e2blage \u00e0 75 \u00b0C (167 \u00b0F), ils fonctionnent dans des conditions standard.<\/p>\n<p>Les conduits peuvent supporter un c\u00e2blage \u00e0 90 \u00b0C (194 \u00b0F) s&#039;ils r\u00e9pondent aux exigences de construction sp\u00e9cifi\u00e9es pour les applications \u00e0 haute temp\u00e9rature.<\/p>\n<p><strong>3.3.2 Conduit de type EB et A<\/strong><\/p>\n<p>Les conduits de type EB et de type A conviennent aux environnements \u00e0 50 \u00b0C (122 \u00b0F) et moins.<\/p>\n<p>Le conduit rigide en PVC de type A prend en charge le c\u00e2blage jusqu&#039;\u00e0 75 \u00b0C (167 \u00b0F).<\/p>\n<p>Lorsqu&#039;ils sont encastr\u00e9s dans du b\u00e9ton dans des tranch\u00e9es ext\u00e9rieures, les types A et EB peuvent \u00eatre utilis\u00e9s avec un c\u00e2blage \u00e9valu\u00e9 jusqu&#039;\u00e0 90 \u00b0C (194 \u00b0F).<\/p>\n<p>Bien que le document ne pr\u00e9cise pas explicitement la plage de temp\u00e9rature des conduits de la s\u00e9rie DB, ses limites op\u00e9rationnelles peuvent \u00eatre d\u00e9duites en les comparant \u00e0 des produits similaires. De nombreux fabricants vont au-del\u00e0 des exigences standard dans leurs conceptions. Par exemple, des tests ont r\u00e9v\u00e9l\u00e9 que les conduits en PVC de Ctube peuvent supporter des temp\u00e9ratures allant de -15 \u00b0C \u00e0 105 \u00b0C, d\u00e9montrant ainsi des performances sup\u00e9rieures aux normes industrielles habituelles.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"34_Other_Requirements\"><\/span>3.4 Autres exigences<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Les SCH 40 et 80 doivent \u00eatre gris, et les conduits en PVC doivent \u00eatre gris ou blancs. Tous les conduits peuvent \u00eatre d&#039;autres couleurs, sous r\u00e9serve d&#039;accord entre les parties concern\u00e9es.<\/p>\n<p>R\u00e9sistance \u00e0 la traction : 5\u00a0000 psi (34,5 MN\/m2)(3,45 kN\/cm2)(3\u00a0515 gf\/mm2) pour les conduits rigides en PVC de s\u00e9rie 40 et 80 et 4\u00a0000 lbf\/po2 (27,6 MN\/m2 ou 2,76 kN\/cm2 ou 2\u00a0812 gf\/mm2) pour les conduits rigides en PVC de type A, de type EB et de type DB.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"4_PVC_Conduit_Application_introduce_SCH_40_SCH_80_Type_EB_Type_DB_Type_A\"><\/span>4. Pr\u00e9sentation des applications de conduits en PVC\u00a0: SCH 40, SCH 80, type EB, type DB, type A<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h4><span class=\"ez-toc-section\" id=\"41_General_Applications_of_PVC_Conduit\"><\/span><strong>4.1 Applications g\u00e9n\u00e9rales des conduits en PVC<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Quel que soit leur type, les conduits en PVC sont largement utilis\u00e9s en int\u00e9rieur comme en ext\u00e9rieur, en installations a\u00e9riennes et souterraines, et dans les zones exigeant r\u00e9sistance \u00e0 la corrosion et durabilit\u00e9. Le choix du type de conduit d\u00e9pend de facteurs tels que la r\u00e9sistance aux chocs, la tol\u00e9rance \u00e0 la pression et la conformit\u00e9 r\u00e9glementaire.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10711\" src=\"https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/undergroud-conduit-application.jpg\" alt=\"application de conduit souterrain\" width=\"800\" height=\"600\" srcset=\"https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/undergroud-conduit-application.jpg 1024w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/undergroud-conduit-application-300x225.jpg 300w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/undergroud-conduit-application-768x576.jpg 768w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/undergroud-conduit-application-16x12.jpg 16w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/undergroud-conduit-application-600x450.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p><strong>4.1.1 Installations industrielles et commerciales<\/strong><\/p>\n<p>Utilis\u00e9 pour prot\u00e9ger le c\u00e2blage \u00e9lectrique dans les entrep\u00f4ts, les usines et les usines de transformation.<\/p>\n<p>Le programme 40 convient aux applications g\u00e9n\u00e9rales o\u00f9 une protection m\u00e9canique mod\u00e9r\u00e9e est suffisante.<\/p>\n<p>L&#039;annexe 80 est recommand\u00e9e pour les environnements pr\u00e9sentant des risques d&#039;impact \u00e9lev\u00e9s, tels que les usines chimiques et les zones o\u00f9 les \u00e9quipements sont fr\u00e9quemment d\u00e9plac\u00e9s.<\/p>\n<p><strong>4.1.2 Garages de stationnement et all\u00e9es<\/strong><\/p>\n<p>Install\u00e9 dans les structures de stationnement, les tunnels et les voies d&#039;acc\u00e8s pour prot\u00e9ger les lignes \u00e9lectriques.<\/p>\n<p>L&#039;annexe 40 est utilis\u00e9e dans les installations sur\u00e9lev\u00e9es ou murales, tandis que<\/p>\n<p>L&#039;annexe 80 est privil\u00e9gi\u00e9e pour les emplacements au niveau du sol soumis \u00e0 l&#039;impact des v\u00e9hicules.<\/p>\n<p><strong>4.1.3 Emplacements corrosifs et dangereux<\/strong><\/p>\n<p>Le conduit en PVC est id\u00e9al pour les stations-service, les raffineries de p\u00e9trole et les installations c\u00f4ti\u00e8res, gr\u00e2ce \u00e0 sa r\u00e9sistance \u00e0 la corrosion, \u00e0 l&#039;humidit\u00e9 et aux produits chimiques.<br \/>\nDans les zones dangereuses (telles que d\u00e9finies par l&#039;article 352.10 du NEC), le programme 80 est requis pour la r\u00e9sistance aux chocs dans les zones expos\u00e9es aux gaz et vapeurs inflammables.<\/p>\n<p><strong>4.1.4 Installations souterraines<\/strong><\/p>\n<p>Utilis\u00e9 dans les r\u00e9seaux de services publics, les passages \u00e0 niveau et les zones \u00e0 fort trafic pour prot\u00e9ger le c\u00e2blage souterrain.<\/p>\n<p>Les conduits de type DB et de type EB sont sp\u00e9cialement con\u00e7us pour les applications souterraines, le type DB \u00e9tant adapt\u00e9 \u00e0 l&#039;enfouissement direct et le type EB n\u00e9cessitant un enrobage en b\u00e9ton pour un support structurel suppl\u00e9mentaire.<\/p>\n<p>Dans les zones \u00e0 haute pression, comme sous les autoroutes ou les pistes d&#039;a\u00e9roport, le conduit de type 80 est souvent utilis\u00e9 pour une r\u00e9sistance accrue, tandis que le conduit de type A est pr\u00e9f\u00e9r\u00e9 lorsqu&#039;une durabilit\u00e9 extr\u00eame est requise dans les structures en b\u00e9ton.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"42_Differences_in_Specialized_Applications\"><\/span>4.2 Diff\u00e9rences dans les applications sp\u00e9cialis\u00e9es<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Bien que tous les types de conduits en PVC partagent des applications communes, les principales diff\u00e9rences r\u00e9sident dans leurs exigences structurelles et leurs m\u00e9thodes d&#039;enfouissement :<\/p>\n<p><strong>4.2.1 Annexe 40 contre Annexe 80<\/strong><\/p>\n<p>Les deux conviennent aux applications g\u00e9n\u00e9rales de conduits \u00e9lectriques.<\/p>\n<p>Le programme 40 est rentable et largement utilis\u00e9 dans les installations standard.<\/p>\n<p>Le mod\u00e8le Schedule 80 offre une \u00e9paisseur de paroi plus importante et est pr\u00e9f\u00e9r\u00e9 dans les environnements \u00e0 haut risque avec des forces d&#039;impact ou d&#039;\u00e9crasement potentielles.<\/p>\n<p><strong>4.2.2 Type DB vs. Type EB<\/strong><\/p>\n<p>Le type DB est con\u00e7u pour un enfouissement direct, \u00e9liminant ainsi le besoin d&#039;un enrobage en b\u00e9ton. Il peut \u00e9galement \u00eatre enterr\u00e9 dans un enrobage en b\u00e9ton.<\/p>\n<p>Le type EB est destin\u00e9 \u00e0 \u00eatre utilis\u00e9 dans des conduits enrob\u00e9s de b\u00e9ton dans des projets commerciaux et municipaux.<\/p>\n<p><strong>4.2.3 Conduit de type A<\/strong><\/p>\n<p>Offre une durabilit\u00e9 accrue pour les r\u00e9seaux souterrains \u00e0 forte charge, y compris les regards, les coffres utilitaires et les dalles de b\u00e9ton structurelles.<br \/>\nConvient aux temp\u00e9ratures extr\u00eames et aux applications exigeantes.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"5_How_to_Choose_Between_SCH_40_SCH_80_Type_DB_Type_EB_and_Type_A\"><\/span>5. Comment choisir entre SCH 40, SCH 80, Type DB, Type EB et Type A<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Lors du choix du conduit en PVC appropri\u00e9 pour votre projet, plusieurs facteurs tels que le co\u00fbt, la durabilit\u00e9, l&#039;environnement d&#039;installation et la conformit\u00e9 aux normes de l&#039;industrie doivent \u00eatre pris en compte.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10708\" src=\"https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/How-to-Choose-Between-SCH-40-SCH-80-Type-DB-Type-EB-and-Type-A-1024x574.jpeg\" alt=\"Comment choisir entre SCH 40, SCH 80, Type DB, Type EB et Type A\" width=\"800\" height=\"448\" srcset=\"https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/How-to-Choose-Between-SCH-40-SCH-80-Type-DB-Type-EB-and-Type-A-1024x574.jpeg 1024w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/How-to-Choose-Between-SCH-40-SCH-80-Type-DB-Type-EB-and-Type-A-300x168.jpeg 300w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/How-to-Choose-Between-SCH-40-SCH-80-Type-DB-Type-EB-and-Type-A-768x431.jpeg 768w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/How-to-Choose-Between-SCH-40-SCH-80-Type-DB-Type-EB-and-Type-A-18x10.jpeg 18w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/How-to-Choose-Between-SCH-40-SCH-80-Type-DB-Type-EB-and-Type-A-600x337.jpeg 600w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/How-to-Choose-Between-SCH-40-SCH-80-Type-DB-Type-EB-and-Type-A.jpeg 1312w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h4><span class=\"ez-toc-section\" id=\"51_Mechanical_Strength_and_Durability\"><\/span>5.1 R\u00e9sistance m\u00e9canique et durabilit\u00e9<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Le SCH 80 est l&#039;option la plus durable, avec ses parois plus \u00e9paisses offrant une r\u00e9sistance sup\u00e9rieure aux chocs. Il est recommand\u00e9 pour les environnements \u00e0 haut risque o\u00f9 le conduit peut \u00eatre expos\u00e9 \u00e0 des contraintes physiques ou \u00e0 des impacts violents.<\/p>\n<p>Le SCH 40, tout en \u00e9tant durable, a une paroi plus fine et est moins r\u00e9sistant aux chocs que le SCH 80, ce qui le rend adapt\u00e9 aux installations \u00e0 usage g\u00e9n\u00e9ral qui ne n\u00e9cessitent pas de protection m\u00e9canique \u00e9lev\u00e9e.<\/p>\n<p>Le type A offre une r\u00e9sistance mod\u00e9r\u00e9e et est con\u00e7u pour r\u00e9pondre aux exigences physiques des applications enrob\u00e9es de b\u00e9ton, ce qui en fait un bon choix pour les installations souterraines qui n\u00e9cessitent un support suppl\u00e9mentaire du b\u00e9ton environnant.<\/p>\n<p>Les types DB et EB sont destin\u00e9s \u00e0 une utilisation souterraine et offrent une durabilit\u00e9 ad\u00e9quate. Le type DB est con\u00e7u pour une pose en enfouissement direct, tandis que le type EB est utilis\u00e9 dans les applications o\u00f9 le conduit est noy\u00e9 dans le b\u00e9ton, offrant une protection contre les chocs dans des conditions difficiles.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"52_Installation_Environment_Underground_vs_Aboveground\"><\/span>5.2 Environnement d&#039;installation : souterrain ou a\u00e9rien<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Installations hors sol : Les SCH 40 et SCH 80 sont tous deux id\u00e9aux pour les applications hors sol, le SCH 80 \u00e9tant pr\u00e9f\u00e9r\u00e9 dans les zones expos\u00e9es \u00e0 de fortes contraintes m\u00e9caniques.<\/p>\n<p>Installations souterraines\u00a0: Les types DB et EB sont plus adapt\u00e9s \u00e0 une utilisation souterraine. Le type DB est con\u00e7u pour un enfouissement direct, tandis que le type EB offre une protection suppl\u00e9mentaire lorsqu&#039;il est encastr\u00e9 dans le b\u00e9ton. Cependant, les types SCH 40 et SCH 80 peuvent \u00eatre utilis\u00e9s sous terre dans les zones \u00e0 fort impact o\u00f9 une r\u00e9sistance m\u00e9canique accrue est n\u00e9cessaire.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"53_Cost_and_Budget_Considerations\"><\/span>5.3 Consid\u00e9rations relatives aux co\u00fbts et au budget<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Le SCH 80 est g\u00e9n\u00e9ralement l&#039;option la plus on\u00e9reuse en raison de ses parois plus \u00e9paisses et de sa durabilit\u00e9 accrue, ce qui en fait le choix id\u00e9al pour les environnements \u00e0 haut risque et \u00e0 fort impact. Le SCH 40 est plus abordable que le SCH 80 et offre une solution \u00e9conomique pour les installations polyvalentes. Les types DB, EB et A sont des options \u00e9conomiques pour les applications souterraines.<\/p>\n<p>Les prix sp\u00e9cifiques doivent \u00eatre consult\u00e9s aupr\u00e8s du fournisseur. Il est important de noter qu&#039;en raison des diff\u00e9rents poids, le temps et le co\u00fbt du transport et de la main-d&#039;\u0153uvre pour l&#039;installation peuvent varier.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"54_Compliance_and_Regulatory_Standards\"><\/span>5.4 Conformit\u00e9 et normes r\u00e9glementaires<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Lors du choix d&#039;un conduit en PVC, il est essentiel de respecter les normes en vigueur, telles que le NEC (Code national de l&#039;\u00e9lectricit\u00e9), qui sp\u00e9cifie les exigences relatives aux mat\u00e9riaux et aux pratiques d&#039;installation. De plus, les codes et r\u00e9glementations locaux du b\u00e2timent, tels que l&#039;OSHA et l&#039;EPA, peuvent imposer des exigences sp\u00e9cifiques pour les installations en environnements dangereux. Le respect de ces normes garantit la s\u00e9curit\u00e9, les performances et la long\u00e9vit\u00e9 du syst\u00e8me de conduits.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"6_Conclusion\"><\/span>6. Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>En conclusion, il n&#039;existe pas de solution id\u00e9ale pour le choix d&#039;un conduit \u00e9lectrique. Le choix du conduit le plus adapt\u00e9 d\u00e9pend des besoins sp\u00e9cifiques du projet, tels que l&#039;environnement d&#039;installation, le budget et la conformit\u00e9 aux normes de s\u00e9curit\u00e9 et r\u00e9glementaires en vigueur. Il est essentiel de prendre en compte des facteurs tels que la r\u00e9sistance, la durabilit\u00e9 et le risque d&#039;exposition \u00e0 des conditions difficiles afin de garantir que le conduit optimise la s\u00e9curit\u00e9 et r\u00e9ponde aux exigences du projet.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10710\" src=\"https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/pvc-conduit-manufacture-Ctube-1024x606.jpg\" alt=\"fabrication de conduits en pvc - Ctube\" width=\"800\" height=\"473\" srcset=\"https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/pvc-conduit-manufacture-Ctube-1024x606.jpg 1024w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/pvc-conduit-manufacture-Ctube-300x178.jpg 300w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/pvc-conduit-manufacture-Ctube-768x454.jpg 768w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/pvc-conduit-manufacture-Ctube-1536x909.jpg 1536w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/pvc-conduit-manufacture-Ctube-18x12.jpg 18w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/pvc-conduit-manufacture-Ctube-600x355.jpg 600w, https:\/\/www.ctube-gr.com\/wp-content\/uploads\/2025\/03\/pvc-conduit-manufacture-Ctube.jpg 1920w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p><span style=\"color: #003473;\"><strong><a style=\"color: #003473;\" href=\"https:\/\/www.ctube-gr.com\/fr\/\">Ctube<\/a><\/strong><\/span> est un fournisseur de conduits \u00e9lectriques, nous proposons une vari\u00e9t\u00e9 de conduits en PVC de haute qualit\u00e9, y compris <a href=\"https:\/\/www.ctube-gr.com\/fr\/conduit-en-pvc-de-la-serie-40-de-ctube-tuyau-electrique-de-la-serie-40-1-2-8-po-x-10-pi-gris\/\"><strong><span style=\"color: #003473;\">Annexe 40<\/span><\/strong><\/a>, <a href=\"https:\/\/www.ctube-gr.com\/fr\/conduit-en-pvc-de-la-serie-80-de-ctube-tuyau-de-conduit-de-1-2-8-po-x-10-pi-gris\/\"><span style=\"color: #003473;\"><strong>Annexe 80<\/strong><\/span><\/a>, <a href=\"https:\/\/www.ctube-gr.com\/fr\/conduit-rigide-en-pvc-de-type-csa-db2-es2\/\"><span style=\"color: #003473;\"><strong>Type DB<\/strong><\/span><\/a>, <a href=\"https:\/\/www.ctube-gr.com\/fr\/conduit-electrique-enterre-direct-de-type-ctube-eb\/\"><span style=\"color: #003473;\"><strong>Type EB<\/strong><\/span><\/a>, et <a href=\"https:\/\/www.ctube-gr.com\/fr\/conduit-electrique-rigide-en-pvc-de-type-ctube\/\"><span style=\"color: #003473;\"><strong>Type A<\/strong><\/span><\/a>, pour r\u00e9pondre aux besoins vari\u00e9s de vos projets. Nous proposons \u00e9galement des solutions sp\u00e9cialis\u00e9es, telles que<a href=\"https:\/\/www.ctube-gr.com\/fr\/conduits-et-raccords-sans-halogene-a-faible-emission-de-fumee\/\"> <strong><span style=\"color: #003473;\">LSZH (faible \u00e9mission de fum\u00e9e et z\u00e9ro halog\u00e8ne)<\/span><\/strong><\/a> conduits pour applications n\u00e9cessitant une s\u00e9curit\u00e9 incendie et une toxicit\u00e9 minimale en cas d&#039;incendie, et <a href=\"https:\/\/www.ctube-gr.com\/fr\/conduits-et-raccords-solaires-en-pvc\/\"><span style=\"color: #003473;\"><strong>PVC solaire<\/strong> <\/span><\/a>conduit con\u00e7u pour les syst\u00e8mes d&#039;\u00e9nergie solaire, offrant une r\u00e9sistance aux UV et une durabilit\u00e9 am\u00e9lior\u00e9es pour une utilisation en ext\u00e9rieur.<\/p>\n<p>Tous nos produits sont rigoureusement test\u00e9s pour r\u00e9pondre aux normes internationales, garantissant des performances fiables dans diverses applications. Pour en savoir plus sur nos produits ou obtenir un devis, n&#039;h\u00e9sitez pas \u00e0 nous contacter\u00a0! Merci de votre lecture et bonne chance pour vos projets.<\/p>","protected":false},"excerpt":{"rendered":"<p>1. Introduction Electrical conduits protect wiring from environmental damage, physical impact, and corrosion. When selecting an electrical conduit, material is often one of the first factors we consider. However, when we&#8217;re choosing between conduits made from the same material, the focus usually shifts to the size and type of the conduit. 1.1 Why Conduit Specifications [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":10781,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_sitemap_exclude":false,"_sitemap_priority":"","_sitemap_frequency":"","_joinchat":[],"footnotes":""},"categories":[143,18],"tags":[149,130,278,279,221],"class_list":["post-10703","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news","category-company-news","tag-electrical-conduit","tag-pvc-conduit","tag-schedule-40","tag-schedule-80","tag-underground-conduit"],"_links":{"self":[{"href":"https:\/\/www.ctube-gr.com\/fr\/wp-json\/wp\/v2\/posts\/10703","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ctube-gr.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ctube-gr.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ctube-gr.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ctube-gr.com\/fr\/wp-json\/wp\/v2\/comments?post=10703"}],"version-history":[{"count":0,"href":"https:\/\/www.ctube-gr.com\/fr\/wp-json\/wp\/v2\/posts\/10703\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ctube-gr.com\/fr\/wp-json\/wp\/v2\/media\/10781"}],"wp:attachment":[{"href":"https:\/\/www.ctube-gr.com\/fr\/wp-json\/wp\/v2\/media?parent=10703"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ctube-gr.com\/fr\/wp-json\/wp\/v2\/categories?post=10703"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ctube-gr.com\/fr\/wp-json\/wp\/v2\/tags?post=10703"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}